Guide To Fire Sprinkler Hydraulic Calculations

By Young Lindsay


Many types of sprinklers that can be classified according to its activation temperature, fast opening, orifice size of sprinkler discharge or flow rate, type of fuse element, jet application form, coverage area waterjet among many other factors involved in risk analysis and project design by the specialist (fire sprinkler hydraulic calculations).

A fire sprinkler is a device for extinguishing fires. Consists of an armature, with a pipe connected to a water pipe pressure. The pipe is closed with a cover subject by a glass capsule filled with a liquid whose boiling point is at a certain temperature (temperature trigger) which is subject against a disperser. When a fire occurs, the liquid boils and the steam breaks the capsule; the lid bounces, exits the water and crashes into the disperser sprinkling the burned area.

It consists of a thermo-sensitive element that is designed to destroy at predetermined temperatures, automatically causing the release of plug and the outlet of a water spray, which should extinguish the flame right in area where it has started. This device can be of two types: side of a disassembled sprayer without bulb or fuse Vista.

The spray outlet is somewhat less sharp slope of the teeth to its plane and a little more in diameter; glass valve polished, chamfered and sprinklers have higher gate outlet. For some time, some of the sprinklers manufacturers to reduce the cost structure used as a sealant rubber gasket. Thus it was not taken into account that over time the elastic properties of rubber deteriorates, and can result in loss of containment. But the worst thing that can happen to the adhesion of rubber sealing surfaces.

Therefore, in case of fire, after the destruction of temperature sensor, the lid remains tightly spray glued to the hull and the water from the system is not received. Such cases were reported in the fire at many places in USA. After that, the producers was conducted large-scale action to recall and replace all sprinklers with rubber sealing rings. In some countries the use of sprinklers with a rubber seal is prohibited.

According to statistics in case of activated fire sprinkler-systems 40% of the time the fire was extinguished by sprinklers, 80% of flames is extinguished when triggered no more than 10 sprinklers. On this basis, taking into account the area, protected by a single sprinkler (12 square meters is determined by the area, which is needed to irrigate the maximum flow of water sprinkler-system. For the first group space area is 120 square meters.

In protected space stretching combustible cord, which when blown open locks that hold the valve, the valve is released and the water flowed to a sprinkler. The device consisted of a cylindrical sealed tanks of about 95 tys.litrov system and 10-inch (250 mm) of the distribution of the aqueduct, covering all parts of the theater. Series of pipes of smaller diameter departed from the distribution pipes and were imbued with a number of half an inch (13 mm) holes through which poured water in case of fire. But the system was not automatic.

First installation started in late XIX century, after the Englishman Stuart Harrison in 1864, has developed a sprinklers. Further development of sprinkler systems associated with the names of Americans Henry Parmelee and Frederick Grinnell. By 1882 in the United States for 200 enterprises was established about 200 thousand. Sprinkler-design Parmelee. During the same year in England the first such installation was witnessed.




About the Author: